Basic principle of electromagnetic coil maintenance


Principle of self-holding solenoid valve of solenoid coil: when coil 1 of self-maintaining solenoid valve is not energized, the power supply is turned off 3 seconds after coil 2 is plugged in, and the self-holding solenoid valve is turned off; When coil 2 of self-maintaining solenoid valve is not energized, coil 1 is plugged in, the power supply is turned off 3 seconds after coil 1 is plugged in, and the self-holding solenoid valve is opened. Working principle diagram with manual calibration solenoid valve: after the solenoid valve needs to be opened, unscrew the protective cover (the middle of the protective cover is a threaded hole type, which is screwed on the linkage rod to be used as a deceived handle), pull the rocker with force, and the valve opens. When the solenoid valve needs to be turned off, the coil should not be plugged in for more than 1 second, and the valve should be turned off quickly within 65ms. Note Name: The solenoid coil of the emergency shut-off valve is plugged in in an instant, the emergency shut-off valve is turned on and turned off quickly, and the valve is locked. Even if the switching power supply is removed, the gate valve is still locked and turned off. It is not easy to turn on the valve fully automatically again, and manual calibration is required on the spot. Because the self-maintaining solenoid valve without long-term plug-in, completed the environmental protection and energy saving, environmental protection. The basic principle of maintenance of straight solenoid valve: when plugging in, the solenoid coil causes the magnetic field force to lift the shut-off piece from the valve block, and the gate valve opens; when the power is turned off, the magnetic field force subsides and the torsion spring

  Solenoid coilPrinciple of self-maintaining solenoid valve: when coil 1 of self-maintaining solenoid valve is not energized, the power supply is turned off 3 seconds after coil 2 is plugged in, and the self-maintaining solenoid valve is turned off; When coil 2 of self-maintaining solenoid valve is not energized, the power supply is turned off 3 seconds after coil 1 is plugged in, and the self-maintaining solenoid valve is opened; Working principle diagram of manual calibration solenoid valve: working principle of natural gas emergency cut-off solenoid valve with manual calibration solenoid valve, unscrew the protective cover (there is a threaded hole in the middle of the protective cover, and screw it on the linkage rod to be used as a deceived handle), pull the rocker with force, and open the valve.: Solenoid valveNeedWhen it is turned off, the coil should not be plugged in for more than 1 second, and the valve should be turned off quickly within 65ms. Note Name: The solenoid coil of the emergency shut-off valve is plugged in in an instant, the emergency shut-off valve is turned on and turned off quickly, and the valve is locked. Even if the switching power supply is removed, the gate valve is still locked and turned off. It is not easy to turn on the valve fully automatically again, and manual calibration is required on the spot. Because the self-maintaining solenoid valve without long-term plug-in, completed the environmental protection and energy saving, environmental protection.

Straight solenoid valve maintenance basic principle: when plugged in,Solenoid coilThe magnetic field force causes the shut-off piece to be lifted from the valve block, and the gate valve is opened; when the power is turned off, the magnetic field force subsides, the torsion spring presses the shut-off piece on the high-pressure gate valve, and the gate valve is turned off. Characteristics: in the vacuum pump, negative pressure, zero pressure can be normal operation, but the diameter is generally not more than 25mm. Layer by layer straight mobile solenoid valve. Basic principle: It is a basic principle of the combination of direct action and pilot action. When there is no pressure difference between the inlet and the inlet and outlet, after the plug-in, the magnetic field force directly mentions the main small valve and the distribution valve closing parts one by one. The valve opens. When the operating pressure difference between the import and export trade is achieved, after the plug-in, the magnetic field force will drive the small valve, the pressure in the lower cavity of the distribution valve will increase, and the pressure in the thoracic and abdominal cavity will decrease, and then the pressure difference will be used to pull the distribution valve upward; when the power is turned off, The hydraulic control valve uses spring force or material pressure to promote the closing part to move downward to close the valve body. Solenoid valve characteristics: in zero pressure difference or vacuum pump, high pressure can also be posture, but the output power is relatively large, mandatory requirements of the level of assembly. Liquid pressure category limit is relatively high, can be arbitrarily assembledNeedComply with the standard of liquid pressure difference.

Natural gas solenoid valve assembly case pay attention to several aspects:

1, before construction should refer to the product manual, whether to meet your application requirements.

2, the pipeline application should be washed clean, the material is not clean should be assembled filter device, in order to avoid the residue hinder the normal operation of the solenoid valve.

3. After long-term use of the solenoid valve, it is convenient to use after draining the condensate; when disassembling, all parts should be arranged in order and then restored to normal installation.

4, the solenoid valve is generally unilateral work, can not be installed, the valve up the arrow is the direction of the pipeline fluid velocity, be sure to keep consistent.

5, the solenoid valve in the frozen site to work again to heat the solution, or set the heat insulation measures.

6, solenoid valve assembly general oil circuit board level,Solenoid coilVertical up, some of the goods can be assembled at will, but if conditions permit, it is more appropriate to be vertical to improve the service life.

7. After the electromagnetic induction coil lead (connector) is connected, it should be determined whether it is firm, and the contact points of the electrical components cannot be vibrated. Loose will cause the solenoid valve to not start. Continuous production work of the solenoid valve, the more appropriate choice of bypass, is conducive to maintenance, not affected by the production and manufacturing.