What is the system structure of the induction coil?


The induction coil system, also known as the closed-circuit electromagnetic induction collective hearing aid system, is the earliest collective hearing aid technology. The hearing aid system consists of a main console, a toroidal induction coil pre-positioned in classrooms, homes and other indoor locations, and a separate hearing aid. It can transmit the voice signal of external wired microphone or FM wireless microphone, as well as the audio signal of recorder, electronic organ and TV.

induction coilThe system, also known as the closed-circuit electromagnetic induction collective hearing aid system, is the earliest collective hearing aid technology. The hearing aid system consists of a main console, a toroidal induction coil pre-positioned in classrooms, homes and other indoor locations, and a separate hearing aid. It can transmit the voice signal of external wired microphone or FM wireless microphone, as well as the audio signal of recorder, electronic organ and TV.

induction coilThe system structure:

(1) Uniformity and direction of magnetic field

The magnetic field of the linear current extends outward from the current generating the magnetic field. The direction of the magnetic field is some closed curve around the current. The magnetic field lines and the resulting magnetic flux are concentric circles, lying on the plane perpendicular to the current, and form a ring flow around the current that generates them. The magnetic field is stronger near the current, and the weaker the magnetic force, the farther the magnetic field current is from the current. The relationship between the direction of the magnetic field lines and the direction of the current can be determined by the right-hand spiral rule. Hold the wire with your right hand and straighten your thumb. If your thumb represents the direction of the current, then your bent finger represents the direction of the magnetic field.

When the coil is installed on the floor and the hearing aid wearer is sitting or standing, in the circuit, the magnetic field lines at the height of the head are mainly horizontal. Thus, at head height, the vertical part of the magnetic field has an almost continuous amount, covering almost the entire room.

Current flow in one direction of the loop has been discussed here. However, the sound is an audio signal. Corresponding to the positive and negative pressures in the original sound wave, the direction is reversed many times per second. Therefore, the circulating magnetic field also reverses many times per second. In fact, according to electromagnetic field theory, it is the constantly changing magnetic current that causes the pickup coil to sense and generate the audio current.

(2) Magnetic field strength

The strength of the magnetic field near the center of the room is proportional to the current in the circuit and the number of circuits, and inversely proportional to the diameter of the circuit. International standards state that the long-term average output power of the magnetic field should be 100mA/M (milliampere/meter). Not less than 70mA/m or more than 140mA/m. This value is the strength of the magnetic field in the vertical plane measured in the circuit 1.2 meters from the floor. The voice allows a peak intensity of 400mA/M and a frequency range of 100hz-5khz.

Many products will have some problems during the installation process, because we cannot control some factors, so we need to ensure the quality of the product. The first problem should be solved in time without affecting the progress of the work. So, we know what factors can causeinduction coilThe problem?

1. The coil should be visually inspected before installation. Before use, check whether the coil structure is firm, whether the wire turns are loose, whether the lead contacts are loose, whether the magnetic core rotates flexibly, whether there is any sliding buckle, etc., and install it after passing the inspection.

2. If the induction coil needs to be fine-tuned during use, the fine-tuning method should be considered. Some coils need to be fine-tuned during use. It is inconvenient to change the number of coils. Therefore, the fine-tuning method should be considered in the selection.

3. Do not change the shape of the induction coil in use. The size and spacing of the coil will affect the original inductance of the coil, especially the coil with higher frequency, that is, the number of coils is small.